  • Caddx Nx 8 Programming Manual 2017; Caddx Nx 8 Programming Manual Download; GE Caddx Alarm Systems. The GE Caddx Networx line of security systems offer many of the features of more complicated alarms, but at very reasonable prices. The 3 main panels are the GE NX-4, NX-6, and the NX-8. The smallest is the NX-4, with 8 on-board zones.
  • NX-8/NX-8E claim blocks of 8 so if a sensor is learned into zone 9 then zones 10 to 16 must also be wireless. Addressing Keypad must be addressed to in order to enter wireless programming, NX panels can have multiple receivers. NX-8E = 8 receivers maximum. NX-8 = 4 receivers maximum. NX-6 = 3 receivers maximum. NX-4 = 4 receivers maximum.

ARMING IN “EXIT” MODE EXIT is used when the user is away from the premises

Select the module to program Since all modules connected to the NX-8V2 are programmed through the keypad, the module you are programming should be the first entry. To select the module to program, enter 0, #. The 0 is the module number of the control, and # is the entry key. Jason of Alarm System Store takes you through a tutorial on programming the Interlogix NetworX NX4, NX6, or NX8 alarm panels. He steps you into programming b. Page 8 NX-4 Control Local Programming Lockout This feature will disable programming of all locations or specified locations from the keypad. 21, page 16) Log Full Report A report can be sent to the central station when the event log is full.

and wants the interior protected (the motion detectors ON).

1. Close all protected doors and windows.

ARMING IN “STAY” MODE STAY is used when the user is inside the premises and

wants protection around the perimeter (the motion

detectors OFF).
2. Press the “STAY” key.

DISARMING SYSTEM Enter code.

2. Enter a master code. The “ready” light will flash.
3. Enter the 2-digit user number (example: “03” for user
4. Enter the new 4-digit user code. Note: To delete a

user code, enter * * * * for a 4-digit code.

5. The ready light will flash. If the code is rejected, the
6. If another user code needs to be programmed,

7. Press the “#” key while the ready light is flashing to

exit the User Code Programming Mode.

BYPASSING ZONES System must be in disarmed state.

2. Enter 1 or 2 digits indicating the zone you wish to

bypass. (Example: Press the “1” key for zone 1,

press “1” then “2” for zone 12.)

4. The corresponding zone light will illuminate indicating

the zone has been bypassed. Repeat steps #2 and #3 for

any other zone(s) that need to be bypassed.

5. Press the “#” key to exit the Bypass Mode. The bypass

light will stop flashing upon exiting the Bypass Mode.

How To Program Caddx Nx 8 Wiring

All zones will automatically be unbypassed each time the

system is disarmed.

VIEW ALARM MEMORY 1. Press “8” “3.” The zone(s) that created the last alarm

2. The ALARM MEMORY feature will flash those zones

that created alarms and will light steady those zones that

were bypassed during the last alarm.


IDENTIFYING TROUBLES

FLASHING ARMED LIGHT The armed light will flash when there has been

an alarm during the previous arm cycle.

POWER LIGHT OFF No AC power.

POWER LIGHT FLASHING Low system battery.

FIRE LIGHT FLASHING Trouble with fire device or wiring.

How To Program Caddx Nx 8 Wiring Kit

ZONE LIGHT FLASHING RAPIDLY A zone is in a trouble condition.

Ge Caddx Nx 8 Manual

SERVICE LIGHT IS ON Press “*2” for further information (indicated by

zone lights).

How To Program Caddx Nx 8 Wiring Diagram

Zone 1 – System fault.

Zone 2 – Zone tamper.

Zone 5 – Zone trouble.

Zone 6 – Telephone trouble.

Zone 7 – Dialer failure.

Zone 8 – System lost time.

Enter “#” to exit mode.

ENTER CODE TO SILENCE TROUBLE BEEPS.

ENTER “*7” TO ATTEMPT TO RESET TROUBLES.

ENTER CODE TO CLEAR SERVICE LIGHT AFTER A PHONE TROUBLE HAS BEEN CLEARED.

SET CLOCK 1. Press “*97.”

3. Enter time as 4-digit military time.